电阻式P系列1A温度保险丝
|
|||||
Model No. |
a |
b |
c |
d |
e |
P-1A-F |
6.5 ± 0.5 |
38 ± 3 |
Φ0.54± 0.05 |
Φ2.1± 0.1 |
2.4 or below |
Model NO. |
Tf(℃) |
Fusing-off Temperature(℃) |
Th(℃) |
Tm(℃) |
Ir(A) |
Ur(V) |
||
IEC |
Corp |
|||||||
P1-1A-F |
102 |
92-102 |
98±2 |
80 |
200 |
1 |
250 |
|
P2-1A-F |
115 |
105-115 |
112±3 |
99 |
200 |
1 |
250 |
|
P3-1A-F |
125 |
115-125 |
120±3 |
105 |
200 |
1 |
250 |
|
P4-1A-F |
130 |
120-130 |
126±2 |
107 |
200 |
1 |
250 |
|
P5-1A-F |
135 |
125-135 |
131±3 |
115 |
200 |
1 |
250 |
|
P9-1A-F |
138 |
128-138 |
135±2 |
118 |
200 |
1 |
250 |
|
P12-1A-F |
145 |
135-145 |
140±2 |
126 |
200 |
1 |
250 |
|
P7-1A-F |
150 |
140-150 |
145±3 |
128 |
200 |
1 |
250 |
|
P15-1A-F |
223 |
213-223 |
218±2 |
190 |
280 |
1 |
250 |
电阻式P系列2A温度保险丝
|
|||||
Model No |
a |
b |
c |
d |
e |
P-F |
9.0± 0.5 |
38 ± 3 |
Φ0.54± 0.05 |
Φ2.5± 0.1 |
3.0 or Below |
Model NO. |
Tf(℃) |
Fusing-off Temperature (℃) |
Th(℃) |
Tm(℃) |
Ir(A) |
Ur(V) |
||
IEC |
Corp |
|||||||
P1-F |
102 |
102+0/-10 |
98±2 |
80 |
200 |
2 |
250 |
|
P2-F |
115 |
115+0/-10 |
112±3 |
99 |
200 |
2 |
250 |
|
P3-F |
125 |
125+0/-10 |
120±3 |
105 |
200 |
2 |
250 |
|
P4-F |
130 |
130+0/-10 |
126±2 |
107 |
200 |
2 |
250 |
|
P5-F |
135 |
135+0/-10 |
131±3 |
115 |
200 |
2 |
250 |
|
P9-F |
138 |
138+0/-10 |
135±2 |
118 |
200 |
2 |
250 |
|
P12-F |
145 |
145+0/-10 |
140±2 |
126 |
200 |
2 |
250 |
|
P7-F |
150 |
150+0/-10 |
145±3 |
128 |
200 |
2 |
250 |
|
P15-F |
223 |
223+0/-10 |
218±2 |
190 |
280 |
2 |
250 |
电阻式P系列3A温度保险丝
|
|||||
Model No |
a |
b |
c |
d |
e |
P-3A-F |
10.0 ± 0.5 |
38 ± 3 |
Φ0.6± 0.02 |
Φ3.0± 0.1 |
3.3 or below |
Model NO. |
Tf (℃) |
Fusing-off Temperature (℃) |
Th(℃) |
Tm (℃) |
Ir(A) |
Ur(V) |
||
IEC |
Corp |
|||||||
P0-3A-F |
84 |
84+0/-10 |
82±2 |
65 |
200 |
3 |
250 |
|
P1-3A-F |
102 |
102+0/-10 |
98±2 |
80 |
200 |
3 |
250 |
|
P2-3A-F |
115 |
115+0/-10 |
112±3 |
95 |
200 |
3 |
250 |
|
P3-3A-F |
125 |
125+0/-10 |
120±3 |
105 |
200 |
3 |
250 |
|
P4-3A-F |
130 |
130+0/-10 |
126±2 |
107 |
200 |
3 |
250 |
|
P5-3A-F |
135 |
135+0/-10 |
131±3 |
115 |
200 |
3 |
250 |
|
P9-3A-F |
138 |
138+0/-10 |
135±2 |
115 |
200 |
3 |
250 |
|
P12-3A-F |
145 |
145+0/-10 |
140±2 |
126 |
200 |
3 |
250 |
|
P7-3A-F |
150 |
150+0/-10 |
145±3 |
128 |
200 |
3 |
250 |
电阻式P系列温度保险丝
|
|||||
Model No. |
a |
b |
c |
d |
e |
P--F |
11.5 ± 0.5 |
38 ± 3 |
Φ0.6± 0.02 |
Φ3.3± 0.2 |
3.6 or below |
Model NO. |
Tf(℃) |
Fusing-off Temperature(℃) |
Th (℃) |
Tm (℃) |
Ir(A) |
Ur(V) |
||
IEC |
Corp |
|
||||||
P0--F |
84 |
84+0/-10 |
82±2 |
65 |
200 |
5 |
250 |
|
P1--F |
102 |
102+0/-10 |
98±2 |
80 |
200 |
5 |
250 |
|
P2--F |
115 |
115+0/-10 |
112±3 |
95 |
200 |
5 |
250 |
|
P3--F |
125 |
125+0/-10 |
120±3 |
105 |
200 |
5 |
250 |
|
P4--F |
130 |
130+0/-10 |
126±2 |
107 |
200 |
5 |
250 |
|
P5--F |
135 |
135+0/-10 |
131±3 |
115 |
200 |
5 |
250 |
|
P9--F |
138 |
138+0/-10 |
135±2 |
115 |
200 |
5 |
250 |
|
P12--F |
145 |
145+0/-10 |
140±2 |
126 |
200 |
5 |
250 |
|
P7--F |
150 |
150+0/-10 |
145±3 |
128 |
200 |
5 |
250 |
Rated functioning temperature(Tf): |
The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection curret.The tolerance according to IEC60691 is from +0 to-10℃.(With Japan Electrical Appliance and Material Law,on the other hand,they must function in the tolerance range of ±7℃.). |
Fusing(cut)-off temperature: |
The fusing-off temperature indicates value measured in silicon oil with a temperature increased by 0.5-1℃ per minute and a detective current 100mA or less. |
Holding temperature(Th): |
The maximum temperature at which a thermal Cutoff will not cause a change in state of conductivity to open circuit while conducting rated current for 168 hours. This rating is required by safety standards based on IEC60691. |
Maximum temperature limit(Tm): |
The maximum temperature at which a Thermal Cutoff can be maimtained for 10 minutes without reclosing.This rating is requirde by safety standards based on IEC60691. |
Rated current(Ir): |
The allowable maximum current which a Thermal Cutoff is able to carry. |
Rated current(Ur): |
The allowable maximum voltage which a Thermal Cutoff is able to be applied. |